Glossary · ISO management system
IAF Mandatory Document (IAF MD)
also: IAF MD, IAF mandatory rules
In short
Binding documents of the former International Accreditation Forum that accreditation bodies and certification bodies must comply with. Since 2026 the Global Accreditation Cooperation (Global ACI) has continued them under its own numbers, to be applied since 28 August 2026. Important examples: Global ACI-TECH-3-001 for organisations with several sites (formerly IAF MD 1), Global ACI-TECH-3-003 for the use of information and communication technology in audits (formerly IAF MD 4), Global ACI-TECH-3-004 for audit time in quality, environmental and occupational health and safety management (formerly IAF MD 5).
Reference: Global ACI, document directory (global-aci.org), as of 10 November 2026
What it means
Standards such as ISO/IEC 17021-1 leave room for interpretation. To make certification bodies work comparably worldwide, the accreditation bodies issued binding additional rules, the Mandatory Documents of the International Accreditation Forum, IAF MD for short. They govern, for example, how organisations with several sites are audited, under which conditions information and communication technology may be used in audits and how audit time is calculated for certain management systems.
The IAF has not existed since 1 January 2026. Its tasks have passed to the Global Accreditation Cooperation, Global ACI for short. It continues the mandatory documents under its own numbers, to be applied since 28 August 2026: Global ACI-TECH-3-001 for multiple sites (formerly IAF MD 1), Global ACI-TECH-3-003 for the use of information and communication technology in audits (formerly IAF MD 4) and Global ACI-TECH-3-004 for audit time in quality, environmental and occupational health and safety management (formerly IAF MD 5). If you come across IAF MD in older documents, you will find the rule today under the new number.
In practice and in the audit
As a company you do not have to comply with these documents yourself; they are addressed to accreditation and certification bodies. They do determine what happens in the certification audit, though. If you plan an audit fully or partly by video conference, the body decides under the rules on information and communication technology whether and how that works. If you have several sites, the sampling rules apply.
For ISO/IEC 42001, ISO/IEC 42006 comes on top, governing audit time, remote shares and the competence of the bodies themselves. Ask your certification body in the quotation which documents it plans by. A body that works properly can tell you the basis of its audit time and its approach to remote shares.
References in standards and law
I cite standards by clause number and in my own words, never verbatim. Legal texts link to EUR-Lex.
- Global ACI-TECH-3-001 (formerly IAF MD 1)Audit and certification of organisations with several sites.
- Global ACI-TECH-3-003 (formerly IAF MD 4)Use of information and communication technology in audits.
- Global ACI-TECH-3-004 (formerly IAF MD 5)Audit time for quality, environmental and occupational health and safety management.
- ISO/IEC 42006:2025, 9.2.4 and Annex ARemote audits and audit time for AI management systems.
Related terms
Further reading in the insights
Matching service
ISO/IEC 42001 Lead Auditor
How certification audits run under the accreditors’ rules is something you learn in the official PECB course for the ISO/IEC 42001 Lead Auditor.
To the courseAuthor: Lars Zimmermann
Term and explanation in my own words. Researched to the best of my knowledge and reviewed for accuracy.